Publications

We maintain this section to inform interested users about independent scientific studies conducted on MetaSystems products. We assume no responsibility or liability regarding the accuracy or correct use of the information or statements provided by external authors. The conclusions or statements expressed in the publications listed are those of the external authors or researchers. The publications may involve user-specific adaptations of MetaSystems products. They are not intended for diagnostic use. For publications covered by the Intended Purpose of Metafer or Ikaros, please refer to the respective instructions for use (IFU).

Filter by Keyword

Filter by Product/Solution

Filtering by 'micronuclei' and TissueFISH

Remove All Filters

International journal of molecular sciences, 24
March, 2023

High Resolution and Automatable Cytogenetic Biodosimetry Using In Situ Telomere and Centromere Hybridization for the Accurate Detection of DNA Damage: An Overview.

M'Kacher, Radhia, Colicchio, Bruno, Junker, Steffen, El Maalouf, Elie, Heidingsfelder, Leonhard, Plesch, Andreas, Dieterlen, Alain, Jeandidier, Eric, Carde, Patrice, Voisin, Philippe

<p>In the event of a radiological or nuclear accident, or when physical dosimetry is not available, the scoring of radiation-induced chromosomal aberrations in lymphocytes constitutes an essential tool for the estimation of the absorbed dose of the exposed individual and for effective triage. Cytogenetic biodosimetry employs different cytogenetic assays including the scoring of dicentrics, micronuclei, and translocations as well as analyses of induced premature chromosome condensation to define the frequency of chromosome aberrations. However, inherent challenges using these techniques include the considerable time span from sampling to result, the sensitivity and specificity of the various techniques, and the requirement of highly skilled personnel. Thus, techniques that obviate these challenges are needed. The introduction of telomere and centromere (TC) staining have successfully met these challenges and, in addition, greatly improved the efficiency of cytogenetic biodosimetry through the development of automated approaches, thus reducing the need for specialized personnel. Here, we review the role of the various cytogenetic dosimeters and their recent improvements in the management of populations exposed to genotoxic agents such as ionizing radiation. Finally, we discuss the emerging potentials to exploit these techniques in a wider spectrum of medical and biological applications, e.g., in cancer biology to identify prognostic biomarkers for the optimal triage and treatment of patients.</p>

Digital object identifier (DOI): 10.3390/ijms24065699

Scientific reports, 10, 2899
February, 2020

A High Throughput Approach to Reconstruct Partial-Body and Neutron Radiation Exposures on an Individual Basis.

Shuryak, Igor, Turner, Helen C., Perrier, Jay R., Cunha, Lydia, Canadell, Monica Pujol, Durrani, Mohammad H., Harken, Andrew, Bertucci, Antonella, Taveras, Maria, Garty, Guy, Brenner, David J.

Biodosimetry-based individualized reconstruction of complex irradiation scenarios (partial-body shielding and/or neutron + photon mixtures) can improve treatment decisions after mass-casualty radiation-related incidents. We used a high-throughput micronucleus assay with automated scanning and imaging software on ex-vivo irradiated human lymphocytes to: a) reconstruct partial-body and/or neutron exposure, and b) estimate separately the photon and neutron doses in a mixed exposure. The mechanistic background is that, compared with total-body photon irradiations, neutrons produce more heavily-damaged lymphocytes with multiple micronuclei/binucleated cell, whereas partial-body exposures produce fewer such lymphocytes. To utilize these differences for biodosimetry, we developed metrics that describe micronuclei distributions in binucleated cells and serve as predictors in machine learning or parametric analyses of the following scenarios: (A) Homogeneous gamma-irradiation, mimicking total-body exposures, vs. mixtures of irradiated blood with unirradiated blood, mimicking partial-body exposures. (B) X rays vs. various neutron + photon mixtures. The results showed high accuracies of scenario and dose reconstructions. Specifically, receiver operating characteristic curve areas (AUC) for sample classification by exposure type reached 0.931 and 0.916 in scenarios A and B, respectively. R for actual vs. reconstructed doses in these scenarios reached 0.87 and 0.77, respectively. These encouraging findings demonstrate a proof-of-principle for the proposed approach of high-throughput reconstruction of clinically-relevant complex radiation exposure scenarios.

Digital object identifier (DOI): 10.1038/s41598-020-59695-9

Int J Radiat Biol, 90(2), 193–202
February, 2014

Inter- and intra-laboratory comparison of a multibiodosimetric approach to triage in a simulated, large scale radiation emergency.

Elizabeth A. Ainsbury, Jenna Al-Hafidh, Ainars Bajinskis, Stephen Barnard, Joan Francesc Barquinero, Christina Beinke, Virginie de Gelder, Eric Gregoire, Alicja Jaworska, Carita Lindholm, David Lloyd, Jayne Moquet, Reetta Nylund, Ursula Oestreicher, Sandrine Roch-Lefévre, Kai Rothkamm, Horst Romm, Harry Scherthan, Sylwester Sommer, Hubert Thierens, Charlot Vandevoorde, Anne Vral, Andrzej Wojcik

<p>The European Union's Seventh Framework Programme-funded project 'Multi-disciplinary biodosimetric tools to manage high scale radiological casualties' (MULTIBIODOSE) has developed a multiparametric approach to radiation biodosimetry, with a particular emphasis on triage of large numbers of potentially exposed individuals following accidental exposures. In November 2012, an emergency exercise took place which tested the capabilities of the MULTIBIODOSE project partners. The exercise described here had a dual purpose: Intercomparison of (i) three biodosimetric assays, and (ii) the capabilities of the seven laboratories, with regards to provision of triage status for suspected radiation exposed individuals.Three biological dosimetry tools - the dicentric, micronucleus and gamma-H2AX (the phosphorylated form of member X of histone H2A, in response to DNA double-strand breaks) foci assays - were tested, in addition to provision of the triage status results (low exposure: 2 Gy) by the MULTIBIODOSE software. The exercise was run in two modes: An initial triage categorisation of samples (based on the first dose estimates for each assay received from each laboratory) followed by collation of the full set of estimated doses (all the results from all modes of each assay carried out by the participating laboratories) calculated using as many modes of operation as possible of the different assays developed during the project. Simulated acute whole body and partial body exposures were included.The results of the initial triage categorisation and the full comparison of assays and methods within and between laboratories are presented here.The data demonstrate that the MULTIBIODOSE approach of applying multiparametric tools to radiation emergencies is valid and effective.</p>

Pharmacogen Genom, 16, 87- 99
2006

Cytogenmetic biomarkers, urinary metabolites and metabolic gene polymorphisms in workers exposed to styrene.

L. Migliore, A. Naccarati, F. Coppedè, E. Bergamaschi, G. De Palma, A. Voho, P. Manini, H. Järventaus, A. Mutti, H. Norppa, A. Hirvonen

The present study comprised a biomonitoring study in 95 workers occupationally exposed to styrene and 98 unexposed controls, employing an integrated approach involving biomarkers of exposure, effect, and susceptibility. Airborne styrene was evaluated at workplace, and urinary styrene metabolites, mandelic acid (MA), phenylglyoxylic acid (PGA), vinylphenols (VPTs) and phenylhydroxyethylmercapturic acids (PHEMAs), were measured as biomarkers of internal dose. Cytogenetic alterations were evaluated by analysing the frequency of chromosomal aberrations (CAs) and micronucleated binucleated cells (MNBN) in peripheral blood lymphocytes. The micronucleus assay was coupled with centromeric fluorescence in situ hybridization to distinguish micronuclei (MN) arising from chromosomal breakage (C- MN) from those harboring whole chromosomes (C+ MN). The possible influence of genetic polymorphisms of xenobiotic-metabolizing enzymes involved in styrene biotransformation (EPHX1, GSTT1, GSTM1, GSTP1) and NAT2 on the cytogenetic endpoints was investigated. The exposed workers showed a significantly higher frequency of MNBN (13.8+/-0.5% versus 9.2+/-0.4%; P<0.001) compared to control subjects. The effect appeared to concern both C- and C+ MN. A positive correlation was seen between the frequency of C+ MN and urinary level of MA+PGA (P<0.05) and VPTs (P<0.001). Chromosome-type CAs positively correlated with airborne styrene level and VPTs (P<0.05), whereas chromatid-type CAs correlated with PHEMAs (P<0.05). Workers bearing GSTM1 null genotype showed lowered levels of PHEMAs (P<0.001). The GSTT1 null genotype was associated with increased MNBN frequencies in the exposed workers (P<0.05) and the fast activity EPHX genotype with a moderate decrease in both MNBN and CAs in the controls. Our results suggest that occupational exposure to styrene has genotoxic effects that are potentiated by the GSTT1 gene deletion. These observations may have relevance considering the risk of lymphatic and haematopoietic malignancies tentatively associated with styrene exposure.

Cytogenet Genome Res, 104, 383- 389
2004

New developments in automated cytogenetic imaging: unattended scoring of dicentric chromosomes, micronuclei, single cell electrophoresis, and fluorescence signals.

C. Schunck, T. Johannes, D. Varga, T. Lörch, A. Plesch

The quantification of DNA damage, both in vivo and in vitro, can be very time consuming, since large amounts of samples need to be scored. Additional uncertainties may arise due to the lack of documentation or by scoring biases. Image analysis automation is a possible strategy to cope with these difficulties and to generate a new quality of reproducibility. In this communication we collected some recent results obtained with the automated scanning platform Metafer, covering applications that are being used in radiation research, biological dosimetry, DNA repair research and environmental mutagenesis studies. We can show that the automated scoring for dicentric chromosomes, for micronuclei, and for Comet assay cells produce reliable and reproducible results, which prove the usability of automated scanning in the above mentioned research fields.